Problem:
Installing 6.5.x CID on Windows 7 triggers a windows Start Up error message like below:
A change to the .NET libraries was implemented deeming the agent service incompatible with Win 7.
Possible resolution - On master or target end point:
- Open service.msc, stop and change “Liquidware Data Service” to manual startup, restart system.
- This will stop the error message but also stop this service functionality.
- Or, replace this service module with the attached build tntdatasvc, restart system.
- I would test this on a test windows 7 desktop before applying it to every machine.
- Extract the service module from the zipped file. (7zip)
- Remove or back up the existing module in C:\Program Files (x86)\Liquidware Labs\Connector ID\tntdatasvc.exe. Make sure to move it out of this directory or delete it.
- Replace with the attached .exe.
- Or wait for our 6.6.0 release.
Product: Stratusphere FIT/UX 6.5.X
Product Version: All
Expires on: 365 days from publish date
Updated: Aug 5, 2021