Problem:
Exporting Inspector Data to Spreadsheet hangs. Evidence of that is the row @ secs count is not incrementing.
The following error is displayed: (93, 82: Before Error: Can't call method "set_tempdir" on an undefined value at ( eval 136 ) line 1923.
Possible resolution:
NOTE: A temporary workaround to this problem is to select a different Export Method, ie: Copy & Paste
A resolution to this issue is the following:
- Logon to the HUB appliance as friend
- Run the following command:
-
sudo chcon -R --type httpd_sys_rw_content_t /opt/tnt/var/mentok
-
- Test the inspector error once more
Product: Stratusphere FIT/UX
Product Version: 6.1.0
Expires on: 365 days from publish date
Updated: November 28, 2018