NOTE: this option is available in the drop-down list in Profile Unity 6.5 and newer.
Problem:
How to run a trigger for " PCoIP disconnect "
There is no "PCoIP disconnect" listed in the Trigger settings
Possible Resolution(s):
1. Edit your configuration and add a new Trigger Point.
Type: Application Close
Module: Portability Save
Application Name: pcoip_server_win32.exe
Delay In Seconds: 0
Interval In Minutes: 0
This example shows saving Portability at "PCoIP disconnect"
Product: ProfileUnity
Product Version: 6.0